Factors Affecting Strain Measurements: Short Notes (Strain Gauges & Indirect Influences)
Strain measurements (commonly with strain gauge-based systems) are affected by both sensor-specific behavior and system/installation conditions. Key influences include temperature effects, mechanical installation (bonding/alignment), gauge non-idealities, and electrical measurement errors such as lead resistance and noise. These factors determine the final measurement accuracy, repeatability, and drift over time.3
A useful mental model is:
Key terms
- temperature compensation
- gauge factor
- transverse sensitivity
- creep
Footnotes
-
Vishay Precision Group – Strain Gauge basics, including mounting/installation and practical considerations (https://www.vishay.com/docs/ardy/ardy-strain-gauges.pdf) - Overview of strain gauge principles and practical installation considerations. ↩
-
HBK (Hottinger Brüel & Kjær) – Strain gauge application notes (temperature effects, wiring/bridge concepts) (https://www.hbm.com/en/solutions/measurement-and-sensor-technologies/strain-gauges/) - General strain gauge solution pages describing key error sources and compensation concepts. ↩
-
Omega Engineering – Strain gauge measurement fundamentals and common errors (https://www.omega.com/en-us/resources/strain-gauge-basics.html) - Practical notes on strain gauge measurements including system/instrument considerations. ↩
Strain Gauge Basics (overview of working and practical factors)
1) Temperature effects (thermal strain + gauge self-heating)
Temperature changes can produce apparent strain in two ways:
- Direct gauge resistance change (material property changes of the foil/gauge) even with no mechanical strain.
- Thermal expansion of the substrate: when the specimen expands/contracts, strain gauges experience strain due to the structural temperature gradient.
Mitigation usually relies on temperature compensation using matched gauges, dummy gauges in a bridge, and proper bridge configuration/excitation control.2
What to watch in practice
- Temperature gradients across the gauge area (not just absolute temperature).
- Variation in ambient vs specimen surface temperature.
- Gauge self-heating from excitation (especially at higher current).
Footnotes
-
HBK (Hottinger Brüel & Kjær) – Strain gauge application notes (temperature effects, wiring/bridge concepts) (https://www.hbm.com/en/solutions/measurement-and-sensor-technologies/strain-gauges/) - General strain gauge solution pages describing key error sources and compensation concepts. ↩ ↩2
-
Omega Engineering – Strain gauge measurement fundamentals and common errors (https://www.omega.com/en-us/resources/strain-gauge-basics.html) - Practical notes on strain gauge measurements including system/instrument considerations. ↩
Pro Tip: Separate “mechanical strain” from “thermal strain”
Use dummy-gauge/bridge compensation and/or perform a zeroing step at the operating temperature to reduce apparent strain from temperature gradients (not only from ambient temperature).
2) Installation and bonding effects (adhesive and mounting stiffness)
Bonding and mounting determine how faithfully the gauge follows the specimen surface strain:
- Bond thickness and uniformity: variations lead to local strain transfer errors.
- Adhesive cure effects: mismatch in cure temperature and final operating temperature can introduce residual strain.
- Mounting stiffness / bending of the backing: can distort how strain is transmitted to the foil.
- Surface preparation (roughness, cleanliness, corrosion): affects adhesive integrity and long-term stability.
These are usually grouped under strain transfer quality and installation workmanship.2
Key terms
- strain transfer
- adhesive creep
- bond line stiffness
Footnotes
-
Vishay Precision Group – Strain Gauge basics, including mounting/installation and practical considerations (https://www.vishay.com/docs/ardy/ardy-strain-gauges.pdf) - Overview of strain gauge principles and practical installation considerations. ↩
-
HBK (Hottinger Brüel & Kjær) – Strain gauge application notes (temperature effects, wiring/bridge concepts) (https://www.hbm.com/en/solutions/measurement-and-sensor-technologies/strain-gauges/) - General strain gauge solution pages describing key error sources and compensation concepts. ↩
3) Gauge geometry and alignment errors (directionality + transverse sensitivity)
Strain gauges are designed to respond primarily to strain along the gauge axis, but real behavior includes:
- transverse sensitivity: strain components perpendicular to the grid can cause output.
- Misalignment between gauge axis and principal strain direction: converts shear/other components into measured longitudinal strain.
- Curvature effects: gauges on curved surfaces experience a different strain distribution than flat approximations.
These effects are especially important near stress concentrators, bending regions, and complex stress states.2
Footnotes
-
Vishay Precision Group – Strain Gauge basics, including mounting/installation and practical considerations (https://www.vishay.com/docs/ardy/ardy-strain-gauges.pdf) - Overview of strain gauge principles and practical installation considerations. ↩
-
Omega Engineering – Strain gauge measurement fundamentals and common errors (https://www.omega.com/en-us/resources/strain-gauge-basics.html) - Practical notes on strain gauge measurements including system/instrument considerations. ↩
4) Non-ideal gauge behavior: gauge factor variation, hysteresis, and aging
Real gauges do not behave perfectly linearly over all conditions.
- gauge factor not constant with temperature and sometimes with strain range.
- Hysteresis: repeated loading/unloading can yield different outputs at the same strain due to mechanical and adhesive effects.
- Aging drift: gradual change in zero output over time due to material and adhesive relaxation.
These contribute to measurement drift and reduced reproducibility, particularly for long-duration monitoring.2
Footnotes
-
HBK (Hottinger Brüel & Kjær) – Strain gauge application notes (temperature effects, wiring/bridge concepts) (https://www.hbm.com/en/solutions/measurement-and-sensor-technologies/strain-gauges/) - General strain gauge solution pages describing key error sources and compensation concepts. ↩
-
Omega Engineering – Strain gauge measurement fundamentals and common errors (https://www.omega.com/en-us/resources/strain-gauge-basics.html) - Practical notes on strain gauge measurements including system/instrument considerations. ↩
5) Creep and relaxation (time-dependent strain transfer)
Creep and stress relaxation in:
- the specimen (e.g., polymers/creep-sensitive metals),
- the adhesive layer,
- and the gauge backing
cause output change even if the applied mechanical load is constant.
This is often modeled as time-dependent strain error and is critical for:
- sustained loads,
- proof testing,
- and structural health monitoring.2
Footnotes
-
Vishay Precision Group – Strain Gauge basics, including mounting/installation and practical considerations (https://www.vishay.com/docs/ardy/ardy-strain-gauges.pdf) - Overview of strain gauge principles and practical installation considerations. ↩
-
HBK (Hottinger Brüel & Kjær) – Strain gauge application notes (temperature effects, wiring/bridge concepts) (https://www.hbm.com/en/solutions/measurement-and-sensor-technologies/strain-gauges/) - General strain gauge solution pages describing key error sources and compensation concepts. ↩
6) Electrical system and instrumentation errors (bridge, wiring, excitation, noise)
Even with perfect strain transfer, the electrical measurement chain can introduce error:
- Wheatstone bridge balance: incomplete balancing causes sensitivity to lead resistance and offset.
- Lead wire resistance/temperature: causes apparent strain/offset if not accounted for (often using 3-wire/4-wire arrangements).
- Excitation voltage instability: scales the output directly with bridge excitation.
- Electrical noise: EM interference, grounding issues, and bandwidth limitations.
- ADC resolution and sampling strategy: affects quantization and dynamic measurement fidelity.
These are commonly discussed under strain-gauge instrumentation and bridge circuit error sources.2
Footnotes
-
HBK (Hottinger Brüel & Kjær) – Strain gauge application notes (temperature effects, wiring/bridge concepts) (https://www.hbm.com/en/solutions/measurement-and-sensor-technologies/strain-gauges/) - General strain gauge solution pages describing key error sources and compensation concepts. ↩
-
Omega Engineering – Strain gauge measurement fundamentals and common errors (https://www.omega.com/en-us/resources/strain-gauge-basics.html) - Practical notes on strain gauge measurements including system/instrument considerations. ↩
How to analyze factors affecting a measured strain value
- 1Step 1
Record ambient temperature, specimen temperature, loading profile (static/dynamic), and expected strain range.
- 2Step 2
Verify gauge orientation, surface preparation, adhesive cure/condition, and bond line thickness.
- 3Step 3
Note hold times and whether drift occurs after load application or after temperature stabilization.
- 4Step 4
Confirm bridge type/configuration, lead arrangement (3-wire/4-wire), bridge balance, and grounding.
- 5Step 5
Inspect excitation stability, filtering/bandwidth, shielding, and measurement resolution.
- 6Step 6
Use dummy gauges/zeroing at operating temperature and compare with reference readings for calibration or verification.
Typical strain measurement error contributors (qualitative)
Relative importance varies by application, but this chart reflects common causes in practice.
Life-cycle view: where errors enter the strain measurement
Gauge & bridge selection
DesignChoose gauge type (temperature compensation), bridge configuration, and expected range."
Mounting & bonding
InstallationSurface preparation, adhesive choice, bond thickness, and gauge alignment."
Zeroing & verification
Calibration/SetupZero at operating temperature, verify bridge balance and wiring scheme."
Loading + environment
OperationMonitor drift from temperature gradients, creep, and noise."
Re-check stability
MaintenanceRecalibrate/verify if long-term drift is observed."
Short notes: common edge cases
Quick revision: factors affecting strain measurements
Knowledge Check
Which factor most directly causes apparent strain output when there is no mechanical loading?